High Voltage Test Equipment

  • GIT-450kVA/150kV PD-free AC Dielectric Test Set

    GIT-450kVA/150kV PD-free AC Dielectric Test Set

    The GIT-450kVA/150kV PD-free AC Dielectric Test Set is an advanced automatic withstand voltage tester designed in accordance with the latest national power industry standards. It utilizes PLC controller technology, 2.4G ISM networking, and an advanced human-machine interface. This test equipment is suitable for power frequency withstand voltage testing and partial discharge testing of high-voltage electrical equipment of 150kV and below.The max. capacitance of tested object is 0.05μF at 150kV.

  • Partial Discharge Test System GDYT series

    Partial Discharge Test System GDYT series

     It widely used in electrical manufacturing, power operation departments, research institutes and universities.

     

     

     

  • GDTF-2700kVA/900kV AC Resonant Test System

    GDTF-2700kVA/900kV AC Resonant Test System

    GDTF-2700kVA/900kV is specially designed for AC withstand voltage test for 500kV or below switch, GIS, instrument transformers and neutral point of main transformers.The system includes Variable frequency power supply, exciting transformer, reactor, and capacitive voltage divider.

  • GDZG-300 DC High Voltage Generator

    GDZG-300 DC High Voltage Generator

    GDZG-300 series of DC high voltage tester is testing DC high voltage for zinc oxide lighting arrester, magnetic blowing arrester, power cables, generators, transformers, switches, and other equipment, which is suitable for electric power branch, power department of factories, scientific research units, railway, chemical industry, power plants.

     

     

  • PD Free Variable Frequency Test System

    PD Free Variable Frequency Test System

    GDYT-350kVA/70kV PD free Resonant Test System is composed of PD free variable frequency power supply, HV measuring box, excitation transformer, isolation transformer, Resonant reactor, and capacitive voltage divider. 

     

     

     

     

     

     

  • GDYD-1210D Professional AC Hipot Test Kit for Insulation Strength Verification

    GDYD-1210D Professional AC Hipot Test Kit for Insulation Strength Verification

    GDYD series AC/DC Hipot Test Set is composed of manual control unit and dry testing transformer (HV unit) which output AC voltage smoothly. When adding a HV diode, it can output DC voltage. Meanwhile, it has many monitoring and protection functions. 

  • GDZG-S DC Hipot Test Set

    GDZG-S DC Hipot Test Set

    GDZG-S series is equipment of testing DC voltage and DC leakage current of water-cooled generator in the situation of water through, which completely overcome the problems of long blow water time, bottom water hard to dry, easy to cause arcing within the coil. The device is light, simple wiring, and easy to read. Polarization compensation voltage is output directly by the case.

  • Partial Discharge Test System GIT series

    Partial Discharge Test System GIT series

    GIT series is widely used for high voltage, big capacity GIS power equipment insulated withstand voltage test, partial discharge test and GIS transformer accuracy test, suitable for GIS substation, GIS power equipment manufacturer, basin type electrical insulator manufacturer.

     

     

     

     

     

     

  • GDYD-55D AC/DC Hipot Test Set

    GDYD-55D AC/DC Hipot Test Set

    GDYD series AC/DC Hipot Test Set is composed of manual control unit and dry testing transformer (HV unit) which output AC voltage smoothly. When adding a HV diode, it can output DC voltage. Meanwhile, it has many monitoring and protection functions. 

  • GDYD-53D 50kV AC DC Dielectric Test Equipment

    GDYD-53D 50kV AC DC Dielectric Test Equipment

    AC hi-pot testing is the effective and direct way to test insulation strength for electrical equipment, apparatus, or machines. It checks dangerous flaws which assure electrical equipment continuous working.

     

  • GDFR-C1 Series AC/DC High Voltage Divider

    GDFR-C1 Series AC/DC High Voltage Divider

    GDFR-C1 series AC/DC digital meter is on-site instrument, which test both AC and DC voltage. It consists of voltage divider and measurement instrument.

     

     

     

  • GDYD-63A Versatile AC/DC Hipot Test Set for Comprehensive Electrical Testing

    GDYD-63A Versatile AC/DC Hipot Test Set for Comprehensive Electrical Testing

    GDYD-63A AC/DC Hipot Test Set is composed of automatic control unit and AC oil testing transformer (HV unit) which output AC voltage smoothly. Meanwhile, it has many monitoring and protection functions. When the short circuit rod of testing transformer is taken out, the output is DC voltage.

123 Next > >> Page 1 / 3

Send your message to us:

Write your message here and send it to us